Formerly know as Shams appliance in Philipsburg St Maarten, we now bring you a new branded appliance factory outlet
An 18,000 BTU 208–230V GE Inverter Ductless Mini-Split (typically in GE's Altitude or Endure series) rated around 21 SEER/SEER2 delivers high-efficiency cooling and heating for spaces between 750 and 1,000 sq ft.
Key System Performance Specifications
| Metric / Parameter | Value / Requirement |
| Cooling Capacity | 18,000 BTU/h (1.5 Tons) |
| Efficiency Rating | ~21 SEER / SEER2 (Inverter Variable-Speed) |
| Power Supply Requirements | 208/230V, 60Hz, 1-Phase |
| Minimum Circuit Ampacity (MCA) | 14A – 20A |
| Max Fuse / Breaker Size (MOP) | 20A – 30A (Double-pole breaker) |
| Refrigerant Line Set Dimensions | 1/4" Liquid Line × 1/2" Suction Line |
| Max Piping Length / Elevation | 83 ft max length / 50 ft max drop |
Core Performance Features
A-PAM DC Inverter Rotary Compressor: Continuously ramps compressor speed up or down to maintain exact room temperatures without power-spiking cycling.
Hydrophilic Blue Fin Coils: Pre-coated outdoor and indoor aluminum coil fins maximize water runoff and resist environmental corrosion.
Built-In Wi-Fi (SmartHQ App): Allows temperature modification, fan control, and scheduling directly from a mobile device.
Quiet Indoor Operation: Multi-speed fan curves produce indoor sound levels as low as 29 to 35 dBA during low-stage cooling.
Electrical & Field Installation Notes
Dedicated Breaker Circuit: Requires a 220V dedicated line from the main service panel to an outdoor local disconnect switch using 12/2 or 10/2 NMB wire.
Interconnect Harness: Requires a 14/4 AWG stranded/shielded 4-conductor control cable run between the condenser and the indoor wall handler for power and data.
Flared Lineset Procedure: Connections are flared; installers must pull a deep vacuum to under 500 microns before cracking open the factory R410A/R454B refrigerant valves.